200kg Heavy Duty Ground Support for Heat Pump

  • Product Code: GS-1, GS-2, GS-3
  • AC bracket material: Galvanized Steel
  • Fasteners: Dacromet coating, achieving 240 hours salt spray test performance
  • Fasteners: Dacromet coated fasteners, more than 7-10 times of traditional electrogalvanizing, hot-dip galvanizing or coating method.
Item code
GS-1, GS-2, GS-3

What it is

This unit is supplied as item code GS-1, GS-2, GS-3. An outdoor unit bracket is the structural frame that carries a condenser, a heat pump or a mini split outdoor unit onto a wall or a floor. It is not a cosmetic accessory — it carries the weight of the machine for the life of the building, it holds the machine level so the compressor and the fan stay in balance, and it is the part responsible for whether that outdoor unit is quiet for the neighbours.

Two families cover the two placements. Wall brackets on galvanized steel carry the unit off the face of a wall, and are selected by the weight of the machine they hold. Ground supports carry the unit on a base or a pad, and are rated in kilograms, which is the only meaningful way to specify them because a heat pump on a roof or a balcony can be several times the weight of the indoor unit it serves.

Stainless 304 is the upgrade that pays for itself on any installation within sight of the sea or on a building where the wall is a feature that must not be stained by rust bleeding down it. Galvanized is the standard for ordinary residential and light commercial work.

Technical specification

Item codeGS-1, GS-2, GS-3

How to choose the right one

  1. Specify by the weight of the outdoor unit, not by its size. A machine with a large cabinet is often not the heaviest one on the market — the tonnage and the compressor type decide the load.
  2. Leave room for service clearance between the unit and the wall; a bracket that puts the coil against the wall is a bracket that will be condemned at the first service visit.
  3. Use 304 stainless on coastal sites, on buildings near a swimming pool, and anywhere the galvanized coating is going to be scratched during installation. Zinc on a scratched edge is a rust stain inside two winters.
  4. For ground or rooftop placement, select the support by its rated load in kilograms and add a margin for wind uplift on an exposed position.
  5. Check the wallfixing substrate — a bracket into a light-weight block or a timber frame is a fixing question, and we will quote the correct anchors separately if you tell us the wall.

Material and finish options

MaterialFinishTypical use
Galvanized steelZinc platingOrdinary residential and light commercial
Stainless steel 304Mill finishCoastal, pool side, exposed facades
Powder coated galvanizedZinc + powder coatArchitectural facades, visible installations
Rubber isolator feetBlack rubberNoise-critical installations

Installation

  1. 1
    Fix the bracket to the structure with the fixings the substrate needs, and check the bracket is level before the unit goes on it.
  2. 2
    Take the outdoor unit off its pallet and lift it onto the bracket with two people, or use a suction lift for a heavy machine.
  3. 3
    Level the unit in both directions and fit the isolating pads or rubber feet where the specification calls for them.
  4. 4
    Leave the service clearance at the back and the sides, and check the condensate and refrigerant lines can be bent without strain.
  5. 5
    Check the fixings and the bracket again after the first heating or cooling season — an outdoor bracket in weather moves, and a bracket that was tight at handover is not always tight after five winters.

Where it is used

Residential
Wall mounted condensers and mini split outdoor units.
Light commercial
Rooftop and balcony heat pump placement.
Hotel and apartment
Facade mounted units with a noise obligation.
Coastal and poolside
304 stainless brackets.

Packaging, shipping and OEM

Minimum order quantityMOQ is normally 300–500 pcs per model for stock items and 500 pcs per model for made-to-order sizes
Lead time25-30 days for standard sizes after order confirmation; tooling for new tooling parts starts around 35 days
SamplesSample pieces can be sent 3-5 days against your specification; courier cost is on the buyer side for the first trial order
PackingStandard export packing: bulk in corrugated cartons with pallet on request; retail colour box and printed barcode available for OEM orders
OEMOEM is available — item code, laser logo, carton print and retail box can all carry your brand
Trade termsFOB Ningbo / Shanghai; T/T 30% deposit before production and 70% against copy of B/L

Frequently asked questions

How do I know which bracket fits my unit?
By the outdoor unit weight and the fixing hole pattern. Send the model or the hole centres and we will confirm the bracket rather than ask you to guess.
Galvanized or stainless?
Galvanized for inland residential work. Stainless 304 for coastal, poolside, and any installation where rust bleeding down the wall matters. The cost difference is small against the replacement cost.
What load rating do I need for a ground support?
The rated load in kilograms must exceed the unit weight with a margin — on an exposed rooftop or an open yard position add for wind uplift. Send the unit weight and the placement and we will confirm the rating.
Can the brackets be powder coated in a colour?
Yes — powder coating over galvanized is available and can be matched to a facade colour for visible installations.
Do you make brackets for unusual units?
Yes, non-standard hole patterns and lengths are produced to order. Send a drawing or the unit dimensions and we will quote; new tooling starts before first production.

Related parts and capabilities

Not sure which variant fits? Send the drawing, the profile width or the outside diameter and we will confirm the part before you order. Email sales@climatecarer.com